Reclamation - All Types
4RSHPA
RECLAMATION SYSTEM (for R-11, 12, 22, 113, 114, 123, 134a, 500, 502)
Reclamation System
with 12,000 pound capacity tank
The 4RSHPA system
is intended for use as a commercial reclamation unit. Through the use
of distillation, separation and filtration processes, the 4RSHPA equipment
will clean refrigerants to ARI 700-96 specifications of purity.
The 4RSHPA system
has two main components, a Condensing Module and a Distillation Module,
assembled on tubular steel frames with casters. The two modules connect
with a flexible hose set and power cords. Two high volume refrigerant
recovery tanks are recommended to complete this reclamation circuit:
one dirty
refrigerant recovery tank to feed liquid to the distillation process and one
refrigerant recovery tank to
receive the condensed reclaimed refrigerant product.
STORAGE
TANKS OF ANY SIZE MADE TO ORDER
Electrical
|
Vapor
Recovery
|
|
Reclamation
Rate
|
|
| 460
- 3 Phase |
R
- 11
|
6.0
#/min.
|
R
- 11
|
5.5
#/min. |
| 380
- 3 Phase |
R
- 12 |
20.0
#/min. |
R
- 12 |
11.5
#/min. |
| 50
or 60 HZ |
R
- 22 |
24.0
#/min. |
R
- 22 |
16.0
#/min. |
| |
R
- 113 |
4.6
#/min. |
R
- 113 |
3.4
#/min. |
| Dimensions |
R
- 114 |
12.5
#/min. |
R
- 114 |
10.5
#/min. |
| 48"
Wide |
R
- 123 |
6.3
#/min. |
R
- 123 |
5.4
#/min. |
| 88"
Long |
R
- 134a |
19.0
#/min. |
R
- 134a |
11.5
#/min. |
| 74"
High |
R
- 500 |
20.0
#/min. |
R
- 500 |
11.0
#/min. |
|
|
R
- 502 |
24.8
#/min. |
R
- 502 |
16.5
#/min. |
| Weight |
|
|
|
|
| Each
module - 1650# |
|
|
|
|
| |
|
|
|
|
Refrigerant
Flow Rates
|
|
|
|
|
Liquid
- All refrigerant @
500 #/min. recovery rate |
ALL
REFRIGERANTS PROCESSED TO ARI 700 SPECIFICATIONS |
|